New_Server() can call Conn_Close() in its error paths,
but that function decrements the number of current active
connections. Thus we need to increment it earlier.
When a server is running with SSL/TLS support compiled in,
it is trivial to crash the server by sending an MOTD request
via another server in the network.
- ONLY servers without ssl/tls support compiled in are not affected.
Disabling SSL in the configuration (no ssl listening ports, etc)
does NOT help.
- servers that are running standalone (i.e., not connected to any
other servers) are not affected, either.
This affects all ngircd releases since ngircd 13 (earlier versions
have no SSL/TLS support).
With this patch ngIRCd displays IPv6 addresses as "[<addr>]:<port>" when
accepting new connections and later, if no successful DNS lookup could
be made (or DNS is disabled altogether).
- Fix formatting of some log messages, mostly punctuation.
- cb_Connect_to_Server(): don't use string concatenation, because it
is not supported by pre-ANSI C compilers ...
The new configuration option "NoIdent" in ngircd.conf can be used to
disable IDENT lookups even when the ngIRCd daemon is compiled with IDENT
lookups enabled.
This patch lets ngIRCd count outgoing connections as well as incoming
connections (up to now only outgoing connections have been counted). This
change is required because the Conn_Close() function doesn't know whether
it closes an outgoing connection or not and therefore would decrement the
counter below zero when an outgoing connection existed -- which would
trigger an assert() call ...
Please note that this patch changes the (so far undocumented but now fixed)
behaviour of the "MaxConnections" configuration option to account the sum
of the in- and outbound connections!
Config option claimed to be 'number of connections' but in reality this
was treated as 'largest file descriptor allowed'.
This also fixes another bug in New_connection, where the
ng_ipaddr_tostr_r error path was missing a return statement.
Up to now ngIRCd accepted CR+LF as well as a single CR or LF in "non RFC
compliant" mode (the default). But ngIRCd became confused when it received
data containing mixed line endings (e. g. "111\r222\n333\r\n").
This patch enables ngIRCd (in "non RFC compliant" mode) to detect CR+LF,
CR, and LF as equally good line termination sequences and to always end the
command after the first one detected.
Some clients (for exmaple Trilian) are that ... broken to send such mixed
line terminations ...
First patch proposed by Scott Perry <scperry@ucsd.edu>,
Thanks to Ali Shemiran <ashemira@ucsd.edu> for testing!
In addition, the "timeout" variable has been removed because it is
unnecessary today: Handle_Buffer() handles all the data it can handle,
and io_dispatch() returns immediately when new data is available. So
we don't have to double-check but better sleep. Pointed out by Florian.
this also obsoletes ListenIPv4 and ListenIPv6 options.
If Listen is unset, it is treated as Listen="::,0.0.0.0".
Note: ListenIPv4 and ListenIPv6 options are still recognized,
but ngircd will print a warning if they are used in the config file.
Also, some plattforms require that ai_socktype
is set in the getaddrinfo() hints structure.
Code cleanup and fix for Bug #83, "ngIRCd chokes on 1-character messages" in
function Handle_Buffer(): the buffer is now correctly cleared when ngIRCd
receives 1-character messages terminated with either CR or LF (in violation
to RFC 2812, section 2.3 "Messages", 5th paragraph).
all references to struct sockaddr/in_addr have been
removed from src/ngircd.
libngipaddr (in src/ipaddr/) hides all the gory details.
See src/ipaddr/ng_ipaddr.h for API description.
struct Conf_Server stored the ip address to connect to
in dotted-decimal notation; but we only need this for connect()
so long-time storage isn't necessary.